'\" t .\" Title: riello_ser .\" Author: [see the "AUTHOR" section] .\" Generator: DocBook XSL Stylesheets vsnapshot .\" Date: 06/21/2026 .\" Manual: NUT Manual .\" Source: Network UPS Tools 2.8.5 .\" Language: English .\" .TH "RIELLO_SER" "8" "06/21/2026" "Network UPS Tools 2\&.8\&.5" "NUT Manual" .\" ----------------------------------------------------------------- .\" * Define some portability stuff .\" ----------------------------------------------------------------- .\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ .\" http://bugs.debian.org/507673 .\" http://lists.gnu.org/archive/html/groff/2009-02/msg00013.html .\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ .ie \n(.g .ds Aq \(aq .el .ds Aq ' .\" ----------------------------------------------------------------- .\" * set default formatting .\" ----------------------------------------------------------------- .\" disable hyphenation .nh .\" disable justification (adjust text to left margin only) .ad l .\" ----------------------------------------------------------------- .\" * MAIN CONTENT STARTS HERE * .\" ----------------------------------------------------------------- .SH "NAME" riello_ser \- Driver for Riello UPS Protocol UPS equipment via serial port connections .SH "SYNOPSIS" .sp \fBriello_ser\fR \-h .sp \fBriello_ser\fR \-a \fIUPS_NAME\fR [\fIOPTIONS\fR] .if n \{\ .sp .\} .RS 4 .it 1 an-trap .nr an-no-space-flag 1 .nr an-break-flag 1 .br .ps +1 \fBNote\fR .ps -1 .br .sp This man page only documents the hardware\-specific features of the riello_ser driver\&. For information about the core driver, see \fBnutupsdrv\fR(8)\&. .sp .5v .RE .SH "SUPPORTED HARDWARE" .sp riello_ser supports all recent Riello UPS, Aros UPS models which use the Riello UPS GPSER and SENTR protocols\&. .sp Older Riello UPS products are not supported\&. .SH "EXTRA ARGUMENTS" .sp You may need to tweak some settings, depending on the make and model of your UPS (see \fBups.conf\fR(5)): .PP \fBlocalcalculation\fR .RS 4 When enabled, driver will calculate values of battery\&.runtime and battery\&.charge "locally" in the driver\&. This is for some Riello models which provide incorrect values in hardware readings, or none at all\&. This "local calculation" is done according to nominal battery capacity, nominal battery voltage, actual battery charge, maximum and actual UPS load\&. .sp You may want to also configure \fIdefault\&.battery\&.voltage\&.low\fR and \fIdefault\&.battery\&.voltage\&.high\fR in case the built\-in default range (from 10\&.7V to 12\&.9V) does not match your hardware, or give a shot to \fIdefault\&.battery\&.voltage\&.nominal\fR (e\&.g\&. \fI24\fR) if your device does not serve that either\&. .if n \{\ .sp .\} .RS 4 .it 1 an-trap .nr an-no-space-flag 1 .nr an-break-flag 1 .br .ps +1 \fBNote\fR .ps -1 .br Lead (PbAc) battery charge graph is not linear, so guesstimated charge value may not be perfectly accurate\&. However it should be good enough to determine battery actual status and roughly estimate the time it can still power the system\&. .sp .5v .RE .if n \{\ .sp .\} .RS 4 .it 1 an-trap .nr an-no-space-flag 1 .nr an-break-flag 1 .br .ps +1 \fBWarning\fR .ps -1 .br This keyword may be deprecated in future releases of the driver, in favor of runtimecal and other settings which it requires (as seen in \fBnutdrv_qx\fR(8), \fBblazer_ser\fR(8) and \fBblazer_usb\fR(8) drivers)\&. .sp .5v .RE .RE .SH "AUTHOR" .sp Massimo Zampieri .SH "SEE ALSO" .SS "Related drivers" .sp \fBriello_usb\fR(8) .SS "The core driver" .sp \fBnutupsdrv\fR(8) .SS "Internet resources" .sp The NUT (Network UPS Tools) home page: https://www\&.networkupstools\&.org/historic/v2\&.8\&.5/