POWERCOM(8) NUT Manual POWERCOM(8) (NAME) powercom - UPS Powercom/Trust/Advice (SYNOPSIS) powercom -h powercom -a UPS_NAME [OPTIONS] (Note) powercom . nutupsdrv(8) . (SUPPORTED HARDWARE) UPS ( UPS USB USB ) . Trust 425/625 Powercom Advice Partner/King PR750 . . USB usbhid- ups(8) . USB NUT (HCL) . (EXTRA ARGUMENTS) ups.conf(5) : linevoltage=value . . - - . 230 . manufacturer=name . . PowerCom . modelname=name . . Unknown . serialnumber=value modelname . Unknown . type=name powercom UPS . . : Trust, Egys, KP625AP, IMP, KIN, BNT, BNT-other OPTI. Trust . BNT-other BNT ( 1500A ) . shutdownArguments={{minutes,seconds},whether_minutes_should_be_used} UPS . n UPS . . . . numOfBytesFromUPS=value UPS: Trust. . methodOfFlowControl=name UPS . . : dtr0rts1, dtr1 no_flow_control. validationSequence={{index1,value1},{index2,value2},{index3,value3}} ( KP625AP Trust Egys.) UPS . UPS ( numOfBytesFromUPS ) . . . frequency={A,B} ( KP625AP Trust Egys.) 1/(A*x+B). x A=1/(x^2) B=0 . . . loadPercentage={BatteryA,BatteryB,LineA,LineB} ( KP625AP Trust Egys.) A*x+B. x A=1 B=0 . . . batteryPercentage={Battery1,Battery2,Battery3,Line4,Line5} ( KP625AP Trust Egys.) (Battery) A*x+B*y+C (Line) D*x+E. x A=1 B=0 C=0 D=1 E=0 . . . voltage={240A,240B,120A,120B} ( KP625AP Trust Egys.) A*x+B . x A=2 B=0 . . . nobt . -- -- UPS . (DEFAULT VALUES FOR THE EXTRA ARGUMENTS) linevoltage = 230 manufacturer = PowerCom modelname = Unknown serialnumber = Unknown type = Trust . BNT-other . Trust numOfBytesFromUPS = 11 methodOfFlowControl = dtr0rts1 validationSequence = {{5,0},{7,0},{8,0}} shutdownArguments = {{0,10},n} frequency = {0.00020997,0.00020928} loadPercentage = {6.1343,-0.3808,4.3110,0.1811} batteryPercentage = {5.0000,0.3268,-825.00,4.5639,-835.82} voltage = {1.9216,-0.0977,0.9545,0.0000} KP625AP numOfBytesFromUPS = 16 methodOfFlowControl = dtr0rts1 validationSequence = {{5,0x80},{7,0},{8,0}} shutdownArguments = {{0,10},n} frequency = {0.00020997,0.00020928} loadPercentage = {6.1343,-0.3808,4.3110,0.1811} batteryPercentage = {5.0000,0.3268,-825.00,4.5639,-835.82} voltage = {1.9216,-0.0977,0.9545,0.0000} Egys numOfBytesFromUPS = 16 methodOfFlowControl = no_flow_control validationSequence = {{5,0x80},{7,0},{8,0}} shutdownArguments = {{0,10},n} frequency = {0.00020997,0.00020928} loadPercentage = {6.1343,-0.3808,1.3333,0.6667} batteryPercentage = {5.0000,0.3268,-825.00,2.2105,-355.37} voltage = {1.9216,-0.0977,0.9545,0.0000} IMP numOfBytesFromUPS = 16 methodOfFlowControl = no_flow_control validationSequence = {{5,0xFF},{7,0},{8,0}} shutdownArguments = {{1,30},y} KIN numOfBytesFromUPS = 16 methodOfFlowControl = no_flow_control validationSequence = {{11,0x4b},{8,0},{8,0}} shutdownArguments = {{1,30},y} BNT numOfBytesFromUPS = 16 methodOfFlowControl = no_flow_control validationSequence = {{11,0x42},{8,0},{8,0}} shutdownArguments = {{1,30},y} BNT-other numOfBytesFromUPS = 16 methodOfFlowControl = no_flow_control validationSequence = {{8,0},{8,0},{8,0}} shutdownArguments = {{1,30},y} frequency = {0.00027778,0.0000} loadPercentage = {1.0000,0.0,1.0000,0.0} batteryPercentage = {1.0000,0.0000,0.0000,1.0000,0.0000} voltage = {2.0000,0.0000,2.0000,0.0000} OPTI numOfBytesFromUPS = 16 methodOfFlowControl = no_flow_control validationSequence = {{5,0xFF},{7,0},{8,0}} shutdownArguments = {{1,30},y} (AUTHORS) o Peter Bieringer o Alexey Sidorov o Keven L. Ates o Rouben Tchakhmakhtchian (SEE ALSO) (The core driver) nutupsdrv(8) (Internet resources) NUT (Network UPS Tools): https://www.networkupstools.org/historic/v2.8.5 Network UPS Tools 2.8.5 06/21/2026 POWERCOM(8)