'\" t
.\" Title: microsol-apc
.\" Author: [see the "AUTHORS" section]
.\" Generator: DocBook XSL Stylesheets vsnapshot
.\" Date: 06/21/2026
.\" Manual: NUT Manual
.\" Source: Network UPS Tools 2.8.5
.\" Language: English
.\"
.TH "MICROSOL\-APC" "8" "06/21/2026" "Network UPS Tools 2\&.8\&.5" "NUT Manual"
.\" -----------------------------------------------------------------
.\" * Define some portability stuff
.\" -----------------------------------------------------------------
.\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
.\" http://bugs.debian.org/507673
.\" http://lists.gnu.org/archive/html/groff/2009-02/msg00013.html
.\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
.ie \n(.g .ds Aq \(aq
.el .ds Aq '
.\" -----------------------------------------------------------------
.\" * set default formatting
.\" -----------------------------------------------------------------
.\" disable hyphenation
.nh
.\" disable justification (adjust text to left margin only)
.ad l
.\" -----------------------------------------------------------------
.\" * MAIN CONTENT STARTS HERE *
.\" -----------------------------------------------------------------
.SH "NAME"
microsol-apc \- Driver for APC Back\-UPS BR UPS equipment
.SH "SYNOPSIS"
.sp
\fBmicrosol\-apc\fR \-h
.sp
\fBmicrosol\-apc\fR \-a \fIUPS_NAME\fR [\fIOPTIONS\fR]
.if n \{\
.sp
.\}
.RS 4
.it 1 an-trap
.nr an-no-space-flag 1
.nr an-break-flag 1
.br
.ps +1
\fBNote\fR
.ps -1
.br
.sp
This man page only documents the hardware\-specific features of the microsol\-apc driver\&. For information about the core driver, see \fBnutupsdrv\fR(8)\&.
.sp .5v
.RE
.SH "SUPPORTED HARDWARE"
.sp
This driver supports the following UPS models:
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
APC Back\-UPS BZ1500\-BR
.RE
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
APC Back\-UPS BZ2200I\-BR
.RE
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
APC Back\-UPS BZ2200BI\-BR
.RE
.sp
In 2009, Schneider Electric acquired Microsol Technologies, and by 2012, the entire Microsol line was being sold under the APC brand\&. This driver supports these newer, APC\-branded models\&. Older equipment should use \fBsolis\fR(8)\&.
.SH "EXTRA ARGUMENTS"
.sp
This driver support the following extra optional settings in the \fBups.conf\fR(5)\&.
.PP
\fBbattext=\fR\fIn\fR
.RS 4
Default = 0, no extra battery, where
n
= Ampere*hour\&.
.RE
.PP
\fBprgshut=\fR\fIn\fR
.RS 4
Default = 0, no programmable shutdown;
1
to enable one\&.
.RE
.SH "COMMANDS"
.PP
\fBshutdown\&.return\fR
.RS 4
Shut down in \&.3 minutes and restart in \&.3 minutes after that\&.
.RE
.PP
\fBshutdown\&.stayoff\fR
.RS 4
Shut down in \&.3 minutes and do not return\&.
.RE
.SH "ISSUES"
.sp
For other APC\-Microsol models, the reported voltages, currents and power will be incorrect, as the communication protocol reports unprocessed data instead of real values, needing model\-specific post\-processing by the driver\&. Monitoring of UPS state (on\-battery/on\-line, critical battery) should work for other models, but is untested\&.
.SH "AUTHORS"
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
Ygor A\&. S\&. Regados
.RE
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
Roberto P\&. Velloso
.RE
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
Silvino B\&. Magalhães
.RE
.SH "SEE ALSO"
.SS "The core driver:"
.sp
\fBnutupsdrv\fR(8)
.SS "Driver for older devices under same brand:"
.sp
\fBsolis\fR(8)
.SS "Internet resources:"
.sp
The NUT (Network UPS Tools) home page: https://www\&.networkupstools\&.org/historic/v2\&.8\&.5/