ipmiseld(8) ipmiseld ipmiseld(8) (NAME) ipmiseld - (SEL) IPMI (SYNOPSIS) ipmiseld [OPTION...] (DESCRIPTION) ipmiseld (SEL System Event Log) (poll) syslog . SEL . (cache) SEL . ipmi-sel(8) . syslog . /etc/freeipmi//ipmiseld.conf . IPMI . FreeIPMI freeipmi(7) . (GENERAL OPTIONS) IPMI . -D IPMIDRIVER, --driver-type=IPMIDRIVER . (out-of-band) LAN LAN_2_0 IPMI 1.5 IPMI 2.0 . (in-band) KCS SSIF OPENIPMI SUNBMC INTELDCMI. --disable-auto-probe IPMI . --driver-address=DRIVER-ADDRESS . DRIVER- ADDRESS <<0x>> (octal) <<0>> . --driver-device=DEVICE . --register-spacing=REGISTER-SPACING . ( = ). --target-channel-number=CHANNEL-NUMBER IPMI . --target-slave-address=SLAVE-ADDRESS (slave address) IPMI . -h IPMIHOST1,IPMIHOST2,..., --hostname=IPMIHOST1[:PORT],IPMIHOST2[:PORT],... . << (HOSTRANGED SUPPORT)>> . (port forwarding) . IPv6 [ADDRESS]:PORT . -u USERNAME, --username=USERNAME . ( ) . USER . -p PASSWORD, --password=PASSWORD . . IPMI 1.5 IPMI 2.0 . -P, --password-prompt . -k K_G, --k-g=K_G K_g BMC IPMI 2.0 . . <<0x>> 'abc' 'abc' '0x616263' . -K, --k-g-prompt k-g . --session-timeout=MILLISECONDS (session timeout) . ( ) . --retransmission-timeout=MILLISECONDS (retransmission timeout) . ( ) . . -a AUTHENTICATION-TYPE, --authentication-type=AUTHENTICATION-TYPE IPMI 1.5 . NONE STRAIGHT_PASSWORD_KEY MD2 MD5. MD5 . -I CIPHER-SUITE-ID, --cipher-suite-id=CIPHER-SUITE-ID (Cipher Suite ID) IPMI 2.0 . Cipher Suite IPMI 2.0 . (payload) . . : 0 - = None = None = None 1 - = HMAC-SHA1 = None = None 2 - = HMAC-SHA1 = HMAC-SHA1-96 = None 3 - = HMAC-SHA1 = HMAC-SHA1-96 = AES-CBC-128 6 - = HMAC-MD5 = None = None 7 - = HMAC-MD5 = HMAC-MD5-128 = None 8 - = HMAC-MD5 = HMAC-MD5-128 = AES-CBC-128 11 - = HMAC-MD5 = MD5-128 = None 12 - = HMAC-MD5 = MD5-128 = AES-CBC-128 15 - = HMAC-SHA256 = None = None 16 - = HMAC-SHA256 = HMAC_SHA256_128 = None 17 - = HMAC-SHA256 = HMAC_SHA256_128 = AES-CBC-128 -l PRIVILEGE-LEVEL, --privilege-level=PRIVILEGE-LEVEL . USER OPERATOR ADMIN. OPERATOR . --config-file=FILE . -W WORKAROUNDS, --workaround-flags=WORKAROUNDS . . <> ( ). << (WORKAROUNDS)>> . --debug . -?, --help . --usage . -V, --version . IPMISELD (IPMISELD OPTIONS) ipmiseld . -v (verbose). SEL . (Generator ID) . SEL . (timeout) . -t SENSOR-TYPE-LIST, --sensor-types=SENSOR-TYPE-LIST SEL . . <> ( ). . ( --list-sensor-types ipmi-sel(8) ) ( ) . -T SENSOR-TYPE-LIST, --exclude-sensor-types=SENSOR-TYPE-LIST SEL . . <> ( ). . ( --list-sensor-types ipmi-sel(8) ) ( ) . --system-event-only ( OEM ). --oem-event-only OEM ( ). --event-state-config-file=FILE . --interpret-oem-data OEM . OEM . OEM OEM . << OEM (OEM INTERPRETATION)>> . --entity-sensor-names (entity id) (instance number) . . 'TEMP' "Processor 1" "Processor 2" . --non-abbreviated-units ( 'Amps' 'A'). ( 'C' ). --event-state-filter=FILTERSTRING . NOMINAL WARNING CRITICAL NA. . <> ( ). --warning-threshold=PERCENTINT SEL . SEL SEL . . . --clear-threshold=PERCENTINT SEL . SEL ipmiseld SEL . . SEL . . SEL SEL ipmi-sel(8) libipmimonitoring(3) . --system-event-format=FORMATSTRING SEL . "SEL System Event: %d, %t, %s, %I, %E" "SEL System Event(%h): %d, %t, %s, %I, %E" . << SEL (SEL LOG FORMAT STRING)>> . --oem-timestamped-event-format=FORMATSTRING OEM SEL . "SEL OEM Event: %d, %t, %I, %o" "SEL OEM Event(%h): %d, %t, %I, %o" . << SEL (SEL LOG FORMAT STRING)>> . --oem-non-timestamped-event-format=FORMATSTRING OEM SEL . "SEL OEM Event: %I, %o" "SEL OEM Event(%h): %I, %o" . << SEL (SEL LOG FORMAT STRING)>> . --poll-interval=SECONDS (poll interval) SEL . ( ) . --log-facility=STRING (log facility) . LOG_DAEMON . LOG_DAEMON LOG_USER LOG_LOCAL0 LOG_LOCAL1 LOG_LOCAL2 LOG_LOCAL3 LOG_LOCAL4 LOG_LOCAL5 LOG_LOCAL6 LOG_LOCAL7. --log-priority=STRING (log priority) . LOG_ERR . LOG_EMERG LOG_ALERT LOG_CRIT LOG_ERR LOG_WARNING LOG_NOTICE LOG_INFO LOG_DEBUG. --cache-directory=DIRECTORY (cache) ipmiseld . SDR . --ignore-sdr SDR. SDR SDR . --re-download-sdr SDR . SDR . --clear-sel SEL . ipmiseld SEL . --threadpool-count=NUM (threads) SEL . --fanout ipmi-sel(8) . . --test-run SEL . SEL syslog (stdout) . --foreground (foreground). SEL syslog (stdout) . SEL (SEL LOG FORMAT STRING) --system-event-format --oem-timestamped-event-format --oem-non-timestamped-event-format . --interpret-oem-data --entity-sensor-names --non-abbreviated-units . SEL . OEM OEM %h - %i - (record ID) %I - (NOMINAL WARNING CRITICAL) OEM %t - H:M:S %d - D-M-YEAR %T - %s - %e - (event data 1) %f - (event data 2) %h - (event data 3) %c - %p - %S - (severity) %E - %k - (event direction) OEM %m - (manufacturer id) OEM OEM %o - OEM %O - OEM ( ) (HOSTRANGED SUPPORT) : prefix[n-m,l-k,...] n < m l < k . ( [] ) . foo[19] foo1 foo9 : foo19. prefixNN -- foo1,foo9 foo[1,9] . : foo[01-05] foo01,foo02,foo03,foo04,foo05 foo[7,9-10] foo7,foo9,foo10 foo[0-3] foo0,foo1,foo2,foo3 ([ ]) (pattern matching) . . "localhost" IPMI . localhost . (GENERAL TROUBLESHOOTING) IPMI . IPMI (IPMI over LAN) BMC . BMC : IP MAC (subnet mask) (LAN privilege) LAN / . IPMI 2.0 K_g . ipmi-config(8) / . IPMI BMC . << (WORKAROUNDS)>> . . . "username invalid" - ( NULL ) . BMC . "password invalid" - ( NULL ) . BMC . "password verification timeout" - . "password invalid" ( ) "session timeout" ( ) . . "k_g invalid" - K_g ( K_g ) . K_g BMC . "privilege level insufficient" - IPMI . . . "privilege level cannot be obtained for this user" - . . BMC . "authentication type unavailable for attempted privilege level" - . . BMC . "cipher suite id unavailable" - BMC . . BMC . "ipmi 2.0 unavailable" - IPMI 2.0 . IPMI 1.5 . "connection timeout" - IPMI . IP IPMI IPMI . . "session timeout" - IPMI . . (retransmission timeout) . BMC . "device not found" - . . "driver timeout" - . . "message timeout" - . . "BMC busy" - BMC . . . "could not find inband device" - . . "driver timeout" - BMC (service processor) . BMC ( ) . "internal IPMI error" - IPMI FreeIPMI . . IPMISELD (IPMISELD TROUBLESHOOTING) SEL 1-Jan-1970 ( SEL) . . (power cycle) . SEL SEL . bmc-device(8) . SEL . "sel config file parse error" - SEL . freeipmi_interpret_sel.conf(5) . (WORKAROUNDS) IPMI IPMI . . () . -W . . . . IPMI . FreeIPMI . assumeio - (memory-mapped) / (system I/O) . . "device not supported" "could not find inband device" . HP ProLiant DL145 G1 . spinpoll - ( KCS) (spin) . (wall clock) IPMI . (context) . authcap - K_g IPMI . K_g . "username invalid" "authentication type unavailable for attempted privilege level" "k_g invalid" . Asus P5M2/P5MT- R/RS162-E4/RX4 Intel SR1520ML/X38ML Sun Fire 2200/4150/4450 ELOM . nochecksumcheck - FreeIPMI (checksum) IPMI . . . . "connection timeout" "session timeout" "password verification timeout" . IPMI 1.5 "noauthcodecheck" . Supermicro X9SCM-iiF Supermicro X9DRi-F Supermicro X9DRFR . idzero - (session ID) . IPMI . "session timeout" . Tyan S2882 BMC M3289 . unexpectedauth - (authcode) . (per-message authentication) . "session timeout" . Dell PowerEdge 2850,SC1425 . forcepermsg - . . "session timeout" . IBM eServer 325 . endianseq - (endianness) . IPMI 1.5 . "session timeout" . Sun ILOM 1.0/2.0 ( ) . noauthcodecheck - FreeIPMI IPMI 1.5 . (hashing) . . . "connection timeout" "session timeout" "password verification timeout" . Xyratex FB-H8-SRAY Intel Windmill Quanta Winterfell Wiwynn Windmill . intel20 - IPMI 2.0 . (padding) HMAC-MD5-128 . "username invalid" "password invalid" "k_g invalid" . Intel SE7520AF2 Intel Server Management Module ( Professional) . supermicro20 - IPMI 2.0 Peppercon IPMI . . "password invalid" . Supermicro H8QME SIMSO . sun20 - IPMI 2.0 . . "password invalid" "bmc error" . Sun Fire 4100/4200/4500 ILOM . "opensesspriv" . opensesspriv - IPMI 2.0 FreeIPMI . (Open Session) IPMI 2.0 RAKP1 . "password invalid" "k_g invalid" "bad rmcpplus status code" "privilege level cannot be obtained for this user" . Sun Fire 4100/4200/4500 ILOM Inventec 5441/Dell Xanadu II Supermicro X8DTH Supermicro X8DTG Intel S5500WBV/Penguin Relion 700 Intel S2600JF/Appro 512X Quanta QSSC-S4R/Appro GB812X-CN Dell C5220 OpenIPMI BMC . "sun20" . integritycheckvalue - (integrity check value) IPMI 2.0 . . "k_g invalid" . Supermicro X8DTG Supermicro X8DTU Intel S5500WBV/Penguin Relion 700 Intel S2600JF/Appro 512X . assumesystemevent - SEL . . "Unknown SEL Record Type" . . HP DL 380 G5 . IPMI 1.5 - IPMI 2.0 IPMI 1.5 . "ipmi 2.0 unavailable" "connection timeout" . IPMI 2.0 IPMI 1.5 --driver-type=LAN_2_0 . HP Supermicro . OEM (OEM INTERPRETATION) --interpret-oem-data . OEM . / . Dell Poweredge 2900, Dell Poweredge 2950, Dell Poweredge R610, Dell Poweredge R710, Fujitsu iRMC S1 and iRMC S2 systems, Intel S5500WB/Penguin Computing Relion 700, Intel S2600JF/Appro 512X, Intel S5000PAL, Inventec 5441/Dell Xanadu II, Inventec 5442/Dell Xanadu III, Quanta S99Q/Dell FS12-TY, Quanta QSSC-S4R/Appro GB812X-CN, Sun X4140 Supermicro X7DBR-3, Supermicro X7DB8, Supermicro X8DTN, Supermicro X7SBI-LN4, Supermicro X8DTH, Supermicro X8DTG, Supermicro X8DTU, Supermicro X8DT3-LN4F, Supermicro X8DTU-6+, Supermicro X8DTL, Supermicro X8DTL-3F, Supermicro X8SIL-F, Supermicro X9SCL, Supermicro X9SCM, Supermicro X8DTN+-F, Supermicro X8SIE, Supermicro X9SCA-F-O, Supermicro H8DGU-F, Supermicro X9DRi-F, Supermicro X9DRI-LN4F+, Supermicro X9SPU-F-O, Supermicro X9SCM-iiF, Wistron/Dell Poweredge C6220. (KNOWN ISSUES) ps(1) /proc . -P -K . FreeIPMI . (brute force) BMC <<>> . . (FILES) /etc/freeipmi//ipmiseld.conf /var/cache/ipmiseld/ (REPORTING BUGS) . (COPYRIGHT) Copyright (C) 2012-2015 Lawrence Livermore National Security, LLC. << >> (GNU GPL) ( ) . (SEE ALSO) freeipmi(7), ipmi-sel(8), ipmiseld.conf(5), bmc-device(8), ipmi- config(8), freeipmi_interpret_sel.conf(5) http://www.gnu.org/software/freeipmi/ ipmiseld 1.6.19 2026-08-27 ipmiseld(8)