'\" t .\" Title: genericups .\" Author: [FIXME: author] [see http://www.docbook.org/tdg5/en/html/author] .\" Generator: DocBook XSL Stylesheets vsnapshot .\" Date: 06/21/2026 .\" Manual: NUT Manual .\" Source: Network UPS Tools 2.8.5 .\" Language: English .\" .TH "GENERICUPS" "8" "06/21/2026" "Network UPS Tools 2\&.8\&.5" "NUT Manual" .\" ----------------------------------------------------------------- .\" * Define some portability stuff .\" ----------------------------------------------------------------- .\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ .\" http://bugs.debian.org/507673 .\" http://lists.gnu.org/archive/html/groff/2009-02/msg00013.html .\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ .ie \n(.g .ds Aq \(aq .el .ds Aq ' .\" ----------------------------------------------------------------- .\" * set default formatting .\" ----------------------------------------------------------------- .\" disable hyphenation .nh .\" disable justification (adjust text to left margin only) .ad l .\" ----------------------------------------------------------------- .\" * MAIN CONTENT STARTS HERE * .\" ----------------------------------------------------------------- .SH "نام (NAME)" genericups \- درایور عمومی دستگاه‌های یوپی‌اس تماسی در NUT .SH "خلاصه دستور (SYNOPSIS)" .sp \fBgenericups\fR \-h .sp \fBgenericups\fR \-a \fIUPS_NAME\fR [\fIOPTIONS\fR] .if n \{\ .sp .\} .RS 4 .it 1 an-trap .nr an-no-space-flag 1 .nr an-break-flag 1 .br .ps +1 \fBنکته\fR .ps -1 .br .sp این صفحه راهنما فقط ویژگی‌های خاص درایور genericups را مستند می‌کند\&. برای اطلاعات بیشتر درباره درایور هسته، به \fBnutupsdrv\fR(8) مراجعه کنید\&. .sp .5v .RE .SH "سخت‌افزارهای پشتیبانی‌شده (SUPPORTED HARDWARE)" .sp این درایور از سخت‌افزارهای تولیدکنندگان مختلفی پشتیبانی می‌کند، زیرا تنها از ساده‌ترین روش‌های سیگنال‌دهی استفاده می‌کند\&. اتصال تماسی (Contact closure) به نوعی رابط اشاره دارد که در آن سیگنال‌های پایه‌ای بالا/پایین (high/low) برای نشان دادن وضعیت ارائه می‌شوند\&. این نوع یوپی‌اس تنها می‌تواند وضعیت برق شهر و باتری را گزارش کند\&. .sp این بدان معناست که در ups\&.status فقط موارد اساسی را دریافت خواهید کرد: OL، OB و LB (برخی از یوپی‌اس‌ها ممکن است از RB و BYPASS نیز پشتیبانی کنند)\&. هر چیز دیگری نیازمند یک یوپی‌اس هوشمندتر است\&. .SH "کابل‌کشی (CABLING)" .sp کابل‌کشی برای هر نوع یوپی‌اس متفاوت است\&. برای اطلاعات درباره آنچه که با یک نوع یوپی‌اس مشخص کار می‌کند، به جدول زیر مراجعه کنید\&. .SH "آرگومان‌های اضافی (EXTRA ARGUMENTS)" .sp این درایور از تنظیمات زیر در \fBups.conf\fR(5) پشتیبانی می‌کند: .PP upstype=\fItype\fR .RS 4 الزامی است\&. درایور را برای نوع خاصی از یوپی‌اس پیکربندی می‌کند\&. برای اطلاعات بیشتر در مورد ورودی‌های موجود، به بخش انواع یوپی‌اس (UPS Types) در ادامه مراجعه کنید\&. .RE .PP mfr=\fIstring\fR .RS 4 اختیاری است\&. ماهیت یک درایور عمومی یوپی‌اس گاهی اوقات به این معنی است که اطلاعات پیش‌فرض سازنده ارتباطی با سخت‌افزار واقعی متصل‌شده ندارد\&. با تنظیم mfr می‌توانید مقداری را که توسط کلاینت‌های ناظر بر این یوپی‌اس دیده می‌شود، تغییر دهید\&. .RE .PP model=\fIstring\fR .RS 4 اختیاری است\&. این گزینه شبیه به mfr در بالا است، اما در عوض رشته مربوط به مدل را بازنویسی می‌کند\&. .RE .PP serial=\fIstring\fR .RS 4 اختیاری است\&. این گزینه نیز شبیه mfr در بالا بوده و برای ثبت رشته شناسایی یوپی‌اس در نظر گرفته شده است\&. عنوان آن «serial» است زیرا معمولاً به این رشته به عنوان شماره سریال اشاره می‌شود\&. .RE .PP sdtime=\fIvalue\fR .RS 4 اختیاری است\&. درایور پس از تنظیم سیگنال خاموش شدن (خاموشی)، به مدت این تعداد ثانیه به توقف می‌پردازد\&. این امر برای برخی از سخت‌افزارهایی که برای فعال کردن توالی خاموشی به یک سطح سیگنال پایدار نیاز دارند، ضروری است\&. .sp رفتار پیش‌فرض درایور خروج فوری است\&. اگر این کار خاموش شدن سخت‌افزار یوپی‌اس شما را به طور مطمئن فعال نمی‌کند، از این تنظیم برای دادن زمان بیشتر به آن جهت واکنش استفاده کنید\&. .RE .if n \{\ .sp .\} .RS 4 .it 1 an-trap .nr an-no-space-flag 1 .nr an-break-flag 1 .br .ps +1 \fBنکته\fR .ps -1 .br .sp مقادیر بسیار بزرگ برای sdtime ممکن است باعث ایجاد هشدارهایی از طرف upsdrvctl شود، در صورتی که منتظر بازگشت درایور بماند و مهلت آن تمام شود\&. .sp .5v .RE .SH "پیکربندی‌های سفارشی (CUSTOM CONFIGURATIONS)" .sp شما می‌توانید با تعریف مقادیر CP، OL، LB و SD پس از تنظیم upstype در \fBups.conf\fR(5)، آن‌ها را بازنویسی کنید\&. .sp برای مثال، برای تنظیم برق کابل روی DTR و مقدار باتری ضعیف روی DCD، به این شکل خواهد بود: .sp .if n \{\ .RS 4 .\} .nf CP = DTR LB = DCD .fi .if n \{\ .RE .\} .sp مقادیر شناخته‌شده برای خطوط ورودی عبارتند از CTS، DCD و RNG\&. مقادیر شناخته‌شده برای خطوط خروجی عبارتند از DTR، RTS و ST\&. برای اطلاعات بیشتر در مورد معنای این سیگنال‌ها، بخش زیر را ببینید\&. .sp این مقادیر را می‌توان برای سیگنال‌های با منطق فعال منفی (Active Low) نقیض کرد\&. به عنوان مثال، LB=\-DCD وضعیت باتری ضعیف را زمانی تشخیص می‌دهد که DCD در سطح بالا (High) نباشد\&. .SH "اطلاعات انواع (TYPE INFORMATION)" .sp اساس تعریف یک یوپی‌اس در این درایور، نحوه استفاده آن از خطوط سریال موجود است\&. اختصاراتی که در ادامه می‌بینید به شرح زیر است: .PP OL .RS 4 برخط (بدون قطعی برق) (نقطه مقابل \fIOB\fR \(em روی باتری) .RE .PP LB .RS 4 باتری ضعیف (کمبود شارژ) .RE .PP RB .RS 4 تعویض باتری .RE .PP BYPASS .RS 4 بای‌پس باتری فعال است یا باتری نصب نشده است .RE .PP SD .RS 4 خاموش کردن بار (قطع خروجی) .RE .PP CP .RS 4 برق کابل (باید وجود داشته باشد تا خواندن کابل معتبر باشد) .RE .PP CTS .RS 4 Clear to Send (آماده برای ارسال)\&. از یوپی‌اس دریافت می‌شود\&. .RE .PP RTS .RS 4 Ready to Send (درخواست ارسال)\&. توسط رایانه ارسال می‌شود\&. .RE .PP DCD .RS 4 Data Carrier Detect (تشخیص حامل داده)\&. از یوپی‌اس دریافت می‌شود\&. .RE .PP RNG .RS 4 Ring indicate (نشانگر زنگ)\&. از یوپی‌اس دریافت می‌شود\&. .RE .PP DTR .RS 4 Data Terminal Ready (ترمینال داده آماده است)\&. توسط رایانه ارسال می‌شود\&. .RE .PP DSR .RS 4 Data Set Ready (مجموعه داده آماده است)\&. از یوپی‌اس دریافت می‌شود\&. .RE .PP ST .RS 4 ارسال یک سیگنال شکست (BREAK) روی خط ارسال داده (transmit data line) .RE .PP NULL .RS 4 غیرفعال کردن این سیگنال\&. سیگنال غیرفعال همیشه در سطح پایین خواهد بود، به جز \fIOL\fR که همیشه در سطح بالا خواهد بود\&. .RE .PP none .RS 4 نام مستعاری برای NULL که با برخی مستندات دیگر مطابقت دارد\&. .RE .sp علامت \- در جلوی نام یک سیگنال (مانند \-RNG) به این معنی است که شرایط مشخص‌شده با یک سیگنال فعال در سطح پایین (Active Low) اعلام می‌شود\&. برای مثال، [LB=\-RNG] یعنی زمانی که خط نشانگر زنگ (Ring indicate) به سطح پایین می‌رود باتری ضعیف است، و زمانی که آن خط در سطح بالا نگه داشته می‌شود باتری سالم (OK) است\&. .SH "انواع یوپی‌اس (UPS TYPES)" .sp 0 = UPSonic LAN Saver 600 .sp .if n \{\ .RS 4 .\} .nf [CP=DTR+RTS] [OL=\-CTS] [LB=DCD] [SD=DTR] .fi .if n \{\ .RE .\} .sp 1 = APC Back\-UPS/Back\-UPS Pro/Smart\-UPS با کابل 940\-0095A/C .sp .if n \{\ .RS 4 .\} .nf [CP=DTR] [OL=\-RNG] [LB=DCD] [SD=RTS] .fi .if n \{\ .RE .\} .sp 2 = APC Back\-UPS/Back\-UPS Pro/Smart\-UPS با کابل 940\-0020B (نکته: گزارش شده که نوع ۲ با کابل 940\-0020C نیز کار می‌کند)\&. .sp .if n \{\ .RS 4 .\} .nf [CP=RTS] [OL=\-CTS] [LB=DCD] [SD=DTR+RTS] .fi .if n \{\ .RE .\} .sp 3 = PowerTech Comp1000 با برق کابل DTR .sp .if n \{\ .RS 4 .\} .nf [CP=DTR] [OL=CTS] [LB=DCD] [SD=DTR+RTS] .fi .if n \{\ .RE .\} .sp 4 = Generic RUPS Model .sp .if n \{\ .RS 4 .\} .nf [CP=RTS] [OL=CTS] [LB=\-DCD] [SD=\-RTS] .fi .if n \{\ .RE .\} .sp 5 = Tripp Lite UPS با رابط Lan2\&.2 (کابل مشکی 73\-0844) .sp .if n \{\ .RS 4 .\} .nf [CP=DTR] [OL=CTS] [LB=\-DCD] [SD=DTR+RTS] .fi .if n \{\ .RE .\} .sp 6 = Best Patriot با کابل INT51 .sp .if n \{\ .RS 4 .\} .nf [CP=DTR] [OL=CTS] [LB=\-DCD] [SD=RTS] .fi .if n \{\ .RE .\} .sp 7 = CyberPower Power99 همچنین Upsonic Power Guardian PG\-500، Belkin Belkin Home Office، F6H350\-SER، F6H500\-SER، F6H650\-SER، کارت مدیریت Eaton Contact \(em پیکربندی ۳ با کابل 66033 (خاموشی کار نمی‌کند) .sp .if n \{\ .RS 4 .\} .nf [CP=RTS] [OL=CTS] [LB=\-DCD] [SD=DTR] .fi .if n \{\ .RE .\} .sp 8 = Nitram Elite 500 .sp .if n \{\ .RS 4 .\} .nf [CP=DTR] [OL=CTS] [LB=\-DCD] [SD=???] .fi .if n \{\ .RE .\} .sp 9 = APC Back\-UPS/Back\-UPS Pro/Smart\-UPS با کابل 940\-0023A .sp .if n \{\ .RS 4 .\} .nf [CP=none] [OL=\-DCD] [LB=CTS] [SD=RTS] .fi .if n \{\ .RE .\} .sp 10 = Victron Lite با کابل crack .sp .if n \{\ .RS 4 .\} .nf [CP=RTS] [OL=CTS] [LB=\-DCD] [SD=DTR] .fi .if n \{\ .RE .\} .sp 11 = Powerware 3115 .sp .if n \{\ .RS 4 .\} .nf [CP=DTR] [OL=\-CTS] [LB=\-DCD] [SD=ST] .fi .if n \{\ .RE .\} .sp 12 = APC Back\-UPS Office با کابل 940\-0119A .sp .if n \{\ .RS 4 .\} .nf [CP=RTS] [OL=\-CTS] [LB=DCD] [SD=DTR] .fi .if n \{\ .RE .\} .sp 13 = RPT Repoteck RPT\-800A/RPT\-162A .sp .if n \{\ .RS 4 .\} .nf [CP=DTR+RTS] [OL=DCD] [LB=\-CTS] [SD=ST] .fi .if n \{\ .RE .\} .sp 14 = سری Online P .sp .if n \{\ .RS 4 .\} .nf [CP=DTR] [OL=DCD] [LB=\-CTS] [SD=RTS] .fi .if n \{\ .RE .\} .sp 15 = Powerware 5119, 5125 .sp .if n \{\ .RS 4 .\} .nf [CP=DTR] [OL=CTS] [LB=\-DCD] [SD=ST] .fi .if n \{\ .RE .\} .sp 16 = Nitram Elite 2002 .sp .if n \{\ .RS 4 .\} .nf [CP=DTR+RTS] [OL=CTS] [LB=\-DCD] [SD=???] .fi .if n \{\ .RE .\} .sp 17 = PowerKinetics 9001 .sp .if n \{\ .RS 4 .\} .nf [CP=DTR] [OL=CTS] [LB=\-DCD] [SD=???] .fi .if n \{\ .RE .\} .sp 18 = TrippLite Omni 450LAN با کابل‌کشی مارتین (Martin\(cqs cabling) .sp .if n \{\ .RS 4 .\} .nf [CP=DTR] [OL=CTS] [LB=DCD] [SD=none] .fi .if n \{\ .RE .\} .sp 19 = Fideltronic Ares Series .sp .if n \{\ .RS 4 .\} .nf [CP=DTR] [OL=CTS] [LB=\-DCD] [SD=RTS] .fi .if n \{\ .RE .\} .sp 20 = Powerware 5119 RM (فایل docs/cables/powerware\&.txt را در سورس‌های NUT بررسی کنید) .sp .if n \{\ .RS 4 .\} .nf [CP=DTR] [OL=\-CTS] [LB=DCD] [SD=ST] .fi .if n \{\ .RE .\} .sp 21 = Generic RUPS 2000 (کابل Megatec M2501) .sp .if n \{\ .RS 4 .\} .nf [CP=RTS] [OL=CTS] [LB=\-DCD] [SD=RTS+DTR] .fi .if n \{\ .RE .\} .sp 22 = تمامی مدل‌های Gamatronic دارای رابط هشدار (همچنین سری CyberPower SL) .sp .if n \{\ .RS 4 .\} .nf [CP=RTS] [OL=CTS] [LB=\-DCD] [SD=DTR] .fi .if n \{\ .RE .\} .sp 23 = باتری پشتیبان عمومی FTTx (فیبر به x) با رابط تله‌متری ۴ سیمه .sp .if n \{\ .RS 4 .\} .nf [CP=RTS] [OL=CTS] [LB=\-DCD] [RB=\-RNG] [BYPASS=\-DSR] [SD=none] .fi .if n \{\ .RE .\} .SH "مدل‌های مشابه (SIMILAR MODELS)" .sp شرکت‌های مختلف تولیدکننده یوپی‌اس، مدل‌هایی با رابط‌های مشابه تولید می‌کنند\&. به نظر می‌رسد کابل RUPS به‌ویژه در انواع یوپی‌اس‌های «چندراهی برقی» (power strip) که در فروشگاه‌های لوازم اداری یافت می‌شوند، بسیار محبوب است\&. اگر یوپی‌اس شما با یکی از ورودی‌های جدول بالا کار می‌کند، اما اطلاعات مدل یا سازنده مطابقت ندارد، نگران نباشید\&. می‌توانید این مورد را به‌راحتی با استفاده از متغیرهای mfr و model که در بالا مستند شده‌اند در \fBups.conf\fR(5) خود اصلاح کنید\&. .SH "آزمایش سازگاری (TESTING COMPATIBILITY)" .sp اگر یوپی‌اس شما در بالا فهرست نشده است، می‌توانید فهرست را بررسی کنید تا گزینه‌ای که کار می‌کند را بیابید\&. در دنیای یوپی‌اس کابل‌ها و رابط‌ها بسیار مجدداً استفاده می‌شوند و ممکن است یک مورد منطبق پیدا کنید\&. .sp برای انجام این کار، ابتدا مطمئن شوید که هیچ چیز مهمی به پریزهای یوپی‌اس وصل نشده است، زیرا ممکن است ناخواسته آن را خاموش کنید\&. حتماً مطمئن شوید رایانه‌ای که استفاده می‌کنید به آن یوپی‌اس متصل نباشد\&. وسیله کوچکی مانند یک لامپ را وصل کنید تا متوجه شوید چه زمانی برق به پریزها ارسال می‌شود\&. .sp اکنون می‌توانید بر اساس مستنداتی که سازنده شما ارائه داده است (در صورت وجود) یک حدس هوشمندانه بزنید، یا اینکه به ترتیب فهرست را بررسی کنید\&. .SS "گام ۱ (Step 1)" .sp یک درایور را برای آزمایش از فهرست انتخاب کنید (اجرای genericups \-h) و به گام ۲ بروید\&. .SS "گام ۲ (Step 2)" .sp درایور را با نوعی که می‌خواهید آزمایش کنید اجرا نمایید، برای مثال: .sp .if n \{\ .RS 4 .\} .nf genericups \-x upstype=n /dev/port .fi .if n \{\ .RE .\} .sp اجازه دهید \fBupsd\fR(8) همگام شود (گزارش syslog را زیر نظر بگیرید)، سپس \fBupsc\fR(8) را اجرا کنید تا ببینید چه چیزی یافته است\&. اگر STATUS درست است (باید برای برخط "OL" باشد)، به گام ۳ بروید، در غیر این صورت به گام ۱ بازگردید\&. .sp روش دیگر این است که genericups را در حالت اشکال‌زدایی (debug) اجرا کنید، برای مثال: .sp .if n \{\ .RS 4 .\} .nf genericups \-DDDDD \-x upstype=n /dev/port .fi .if n \{\ .RE .\} .sp در این حالت، درایور در پیش‌زمینه اجرا می‌شود و وضعیت برق شهر و باتری یوپی‌اس را به طور مداوم نمایش می‌دهد\&. .SS "گام ۳ (Step 3)" .sp یوپی‌اس را از پریز برق دیوار/برق شهری جدا کنید\&. اگر یک پریز کلیددار بین آن و دیوار داشته باشید این کار ساده‌تر است، اما برای آزمایش می‌توانید دوشاخه را نیز بکشید\&. لامپ باید روشن بماند و وضعیت باید به «OB» تغییر کند\&. اگر لامپ خاموش شد یا وضعیت ظرف حدود ۱۵ ثانیه به «OB» تغییر نکرد، به گام ۱ برگردید\&. در غیر این صورت، به گام ۴ بروید\&. .SS "گام ۴ (Step 4)" .sp در این مرحله، می‌دانیم که OL و OB کار می‌کنند\&. حتی اگر هیچ چیز دیگری پس از این مرحله کار نکند، دست‌کم می‌دانید که مقدار OL/OB شما چه باید باشد\&. .sp صبر کنید تا یوپی‌اس شروع به هشدار دادن درباره کمبود شارژ باتری کند\&. بسته به ظرفیت باتری یوپی‌اس شما و توان لامپ، این ممکن است کمی طول بکشد\&. در نقطه‌ای باید هشدارهای صوتی بشنوید\&. هنگامی که این اتفاق افتاد، STATUS باید ظرف ۱۵ ثانیه «OB LB» را نشان دهد\&. اگر نشان نداد، به گام ۱ برگردید، در غیر این صورت به گام ۵ بروید\&. .SS "گام ۵ (Step 5)" .sp تا اینجای کار: OL کار می‌کند، OB کار می‌کند، و LB هم کار می‌کند\&. .sp در حالی که یوپی‌اس روی باتری کار می‌کند، درایور genericups را با سوییچ \-k اجرا کنید تا آن را خاموش کند\&. .sp .if n \{\ .RS 4 .\} .nf genericups \-x upstype=n \-k /dev/port .fi .if n \{\ .RE .\} .sp اگر یوپی‌اس لامپ را خاموش کرد، کار شما تمام است\&. در این مرحله، تأیید کرده‌اید که توالی خاموشی در واقع همان کاری را می‌کند که می‌خواهید\&. می‌توانید استفاده از درایور genericups را با این شماره نوع برای عملیات عادی شروع کنید\&. .sp شما باید از یافته‌های خود برای افزودن یک بخش به ups\&.conf خود استفاده کنید\&. در اینجا یک مثال سریع آمده است: .sp .if n \{\ .RS 4 .\} .nf [myups] driver = genericups port = /dev/ttyS0 upstype = 1 .fi .if n \{\ .RE .\} .sp مقادیر port و upstype را متناسب با سیستم خود تغییر دهید\&. .SH "پشتیبانی جدید (NEW SUPPORT)" .sp اگر توالی آزمایش بالا ناموفق بود، احتمالاً باید یک ورودی جدید برای پشتیبانی از سخت‌افزار خود ایجاد کنید\&. تمام انواع یوپی‌اس از جدول موجود در فایل genericups\&.h در درخت سورس‌کد تعیین می‌شوند\&. .sp در یک پورت سریال استاندارد ۹ پین، ۶ خط وجود دارد که به عنوان سطوح استاندارد سیگنال «بالا/پایین» (high/low) استفاده می‌شوند\&. ۴ مورد از آن‌ها ورودی هستند (به رایانه، از یوپی‌اس)، و ۲ تای دیگر خروجی هستند (به یوپی‌اس، از رایانه)\&. ۳ تای دیگر خطوط دریافت/ارسال و اتصال زمین (گراند) هستند\&. .sp توجه داشته باشید که بسیاری از سازندگان، پین‌ها را در داخل کابل بازنگاشت (remap) می‌کنند\&. اگر شکی دارید، بررسی سریع با یک مولتی‌متر باید مشخص کند که کابل مستقیم (straight\-through) است یا خیر\&. نکته دیگری که باید در نظر داشت این است که برخی کابل‌ها قطعات الکترونیکی درون خود دارند تا کارهای خاصی انجام دهند\&. برخی از آن‌ها دارای مقاومت‌ها و ترانزیستورهایی هستند تا رفتار را بسته به آنچه توسط رایانه تأمین می‌شود، تغییر دهند\&. .SH "نکات مربوط به مدل‌های خاص (SPECIFIC MODEL NOTES)" .sp این نکات توسط کاربران این درایور ارسال شده است\&. .sp سری Centralion CL ممکن است در صورتی که درایور در هنگام کار یوپی‌اس روی باتری راه‌اندازی شود، برق بار را قطع کند زیرا تنظیمات پیش‌فرض خطوط شامل توالی خاموشی است\&. \- نیل مولر (Neil Muller) .sp مدل Tripp\-Lite Internet Office 700 باید به‌جای کابل خاکستری 73\-0743 با کابل مشکی 73\-0844 استفاده شود\&. این ورودی باید با هر یک از مدل‌های آن‌ها با رابط Lan 2\&.2 کار کند \(em برچسب کنار کانکتور DB9 روی یوپی‌اس را ببینید\&. \- استیون براون (Stephen Brown) .sp نوع ۵ باید با رابط Tripp\-Lite Lan 2\&.1 و کابل 73\-0724 کار کند\&. این مورد با OmniSmart 675 PNP روی ردهت ۷\&.۲ آزمایش شده است\&. \- کیو گیزه (Q Giese) .sp انواع ۷ و ۱۰ هر دو باید با PhoenixTec A1000 کار کنند\&. .SH "اشکالات (BUGS)" .sp هیچ راهی برای تشخیص مطمئن یک یوپی‌اس اتصال تماسی (contact\-closure) وجود ندارد\&. این بدان معناست که درایور حتی در صورت عدم شناسایی یوپی‌اس نیز بدون مشکل راه‌اندازی می‌شود\&. همچنین به این معنی است که اگر اتصال بین یوپی‌اس و رایانه قطع شود، ممکن است نتوانید این موضوع را در نرم‌افزار متوجه شوید\&. .sp اکثر یوپی‌اس‌های اتصال تماسی در صورت وجود برق شهری، برق بار را قطع نخواهند کرد\&. این موضوع می‌تواند هنگام استفاده از سیستم‌های ثانویه \fBupsmon\fR(8) شرایط رقابتی (race condition) ایجاد کند\&. برای اطلاعات بیشتر، صفحه راهنمای \fBupsmon\fR(8) را ببینید\&. .sp راه‌حل هر دوی این مشکلات، ارتقا به نوعی از یوپی‌اس با پروتکل هوشمند است که امکان تشخیص و قطع و وصل مناسب بار طبق دستور را فراهم می‌کند\&. .SH "همچنین ببینید (SEE ALSO)" .SS "درایور هسته (The core driver)" .sp \fBnutupsdrv\fR(8) .SS "منابع اینترنتی (Internet resources)" .sp صفحه اصلی ابزارهای یوپی‌اس شبکه (NUT): https://www\&.networkupstools\&.org/historic/v2\&.8\&.5